Skip to main content

Table 3 Diagnostic accuracy of lung ultrasound scores to detect EVLWi > 15 ml/kg

From: The diagnostic accuracy of lung ultrasound to determine PiCCO-derived extravascular lung water in invasively ventilated patients with COVID-19 ARDS

Score

Score cut off

AUROCC (95% CI)

Sensitivity (95% CI)

Specificity (95% CI)

PPV (95% CI)

NPV (95% CI)

Global LUS

11

0.73 (0.52–0.94)

0.91 (0.90–0.92)

0.29 (0.14–0.44)

0.50 (0.44–0.56)

0.80 (0.78–0.83)

LUS–ARDS

37

0.85 (0.70–1.00)

0.91 (0.90–0.92)

0.71 (0.67–0.76)

0.64 (0.59–0.69)

0.90 (0.89–0.91)

Anterior–lateral LUS

8

0. 79 (0.58–1.0)

0.91 (0.90–0.92)

0.57 (0.50–0.64)

0.63 (0.57–0.68)

0.89 (0.87–0.90)

  1. Summary of the diagnostic accuracy measures of the 12-region global LUS and LUS–ARDS scores and the reduced 8-region anterior–lateral LUS score to detect severe pulmonary edema (EVLWi > 15 ml/kg) at the respective cutoff values. ARDS  Acute Respiratory Distress Syndrome, AUROCC  area under the receiver operating curve, EVLWi  extravascular lung water index, LUS  lung ultrasound, NPV  negative predictive value, PPV  positive predictive value